SPON COMMUNICATIONS: BLAZING A TRAIL IN INGENIOUS IP PA SYSTEM DESIGNS

SPON Communications: Blazing A Trail in Ingenious IP PA System Designs

SPON Communications: Blazing A Trail in Ingenious IP PA System Designs

Blog Article

Network PA System for tool to large-scale tasks



Intro


The XC-9000 system is a completely electronic network PA system based upon the TCP/IP method. By leveraging the TCP/IP protocol, the system makes sure the correct and reliable transmission of all data packages. Not just can it make use of existing computer networks, such as LANs or the Net, to send broadcast signals, however additionally it can also be released on a committed broadcasting network.


A single-server system can sustain up to 3000 terminals and permits for web server plunging. There are no limitations on the simultaneous program channels, achieving real full electronic broadcasting.


System Features



Versatile PA System Style


The PA system style is basic, including solution monitoring software application, network microphones, network amplifiers, network audio speakers, and other devices.All equipment is attached by means of the TCP/IP intranet protocol, enabling versatile configuration and easy administration of the system, with complimentary control over program content, network devices, and regions with the network.


Spon CommunicationsSpon Communications
Comprehensive Sound Management


The audio monitoring software application consists of built-in attributes for developing program strategies, versatile zoning, and pre-scheduled broadcasts.It supports 24-hour programming, enabling changing setups during all day


Versatile Audio Resource Support


The system supports numerous forms of audio sources for sending out notices like real-time speech and BGM playback. Sound resources can originate from digital music applications, CD/DVD gamers, microphones, and so on. Furthermore, the system gives diverse features of supporting various broadcasting features such as arranged broadcasting, zoned broadcasting, and emergency broadcasting.


Fire Alarm System System Combination


The system has an emergency alarm feature and can be integrated into an emergency alarm system. When the alarm central device receives the alarming signals, the cable will certainly transmit the signal to gadgets, which triggers the XC-9000, sending signals to audio speakers


Users might select to predetermined setups to turn on full-area or zoned alarms in emergency situations. The alarm system voices can be found in several forms and might be modified catering to needs. For instance, users can change language setups, upload and modify their audio resources according to specific demands, such as intruding alarms, fire alarms or air aid alarms, etc





Fire Alarm System System Combination


The system has a fire alarm feature and can be incorporated into a fire alarm system. When the alarm system main system gets the worrying signals, the cable will certainly transmit the signal to gadgets, which causes the XC-9000, sending signals to speakers


Users can select to preset setups to turn on full-area or zoned alarms in emergency situations. The alarm voices can be found in numerous kinds and can be edited satisfying requirements. As an example, users can alter language setups, upload and edit their audio resources according to specific needs, such as intruding alarm systems, smoke alarm or air aid alarms, etc





Application Control for System Procedures


The system enables mobile app login and use, enabling individuals to start programs and various other operations to authorized terminals through the server software application, ensuring a convenient and structured experience.


Integrated SIP Compatibility


The system not just enables SIP phones to log in, yet likewise can be attached to third-party SIP web server or IPPBX, which develops a totally incorporated and suitable interaction system with smooth assimilation right into existing systems.


Open SDK


When large job like wise park takes place, the system supplies an open SDK incorporated right into third-party application systems - IP Speaker


System Facilities



Main Functions


Scheduled Playback


The system is able to automatically transmit according to the set up tasks as long as customers publish the audio apply for each amount of time of the day to the server and develop a playback timetable.


Area Broadcasting


The system can randomly separate a few network tools right into different zones to play specified audio programs or send statements to any kind of marked area. navigate to this website The volume of each tool can be from another location changed.


Real-time Broadcasting


The system can catch and broadcast radio programs or various other exterior audio sources in real-time, and at the same time relayed them in sync.


Smoke Alarm Assimilation


The system can be integrated with the emergency alarm system for control. When an emergency alarm signal is set off, it instantly activates the emergency broadcast function and supports adjacent flooring alarm systems. It also permits for hand-operated emergency situation broadcasting by clicking a single switch.


SIP Phone Integration


The system can be integrated with SIP web servers, permitting real-time speech of voice broadcasting using SIP phones to send out news anytime and anywhere.


CCTV Integration


The electronic gadgets such as IP POE Audio speakers embraces the international conventional ONVIF procedure, which allows their voices to be broadcast by means of VMS systems. The terminals can likewise be incorporated with CCTV systems for synchronized program.


Key Products



Audio Management Software XC-9000


B/S architecture, sustains cross-platform applications.
Covers conventional broadcasting system operates, permitting for dividing administration.
Unified administration of terminals within the system, viewing work standing, and batch quantity change, etc.
Supports structure multi-level web server designs, releasing monitoring according to user geographical areas.
Gives SDK development bundles for second development and assimilation with more information various other system platforms.


Network Paging Console XC-9038N


Power: DC12V/1.5 A.
Present: 4-inch touchscreen, resolution 480 * 480.
Interaction Protocols: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 80dB.
Regularity Response: 100Hz~ 16KHz.
Running Temperature: 0~ 45 ℃.
Dimensions: 144 * 144 * 34.1 mm.


Network Paging Console XC-9037N


Power Supply: DC12V/1.5 A.
Show: 4-inch touchscreen, resolution 480 * 480.
Interaction Procedures: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 80dB.
Frequency Response: 100Hz~ 16KHz.
Operating Temperature level: 0~ 45 ℃.
Measurements: 144 * 144 * 34.1 mm.


Network Horn Speaker GEN-6391A03


Power Supply: DC24V/2.7 A or POE.
Communication Procedure: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Ratio: > 80dB.
Frequency Action: 100Hz~ 18KHz.
Intercom: Sustained, Built-in Microphone.
Operating Temperature: -20~ 50 ℃.
Measurements: 283.1 * 224.3 * 269mm.


Network Ceiling Audio Speaker GEN-6211A03


Power Supply: DC 24V/1A or POE.
Interaction Procedures: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Proportion: > 80dB.
Regularity Action: 100Hz~ 18KHz.
Operating Temperature level: -20 to 50 ° C.
Dimensions: φ213 x 165mm.


Network Wall Mount Audio Speaker GEN-6011A03


Power Supply: DC24V/1A or POE.
Interaction Method: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Proportion: > 80dB.
Frequency Response: 100Hz~ 18KHz.
Operating Temperature level: -20~ 50 ℃.
Dimensions: 193x151.5 x292mm.


Network Column Speaker GEN-6191A03




Power Supply: DC24V/1A or POE.
Interaction Method: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 90dB.
Frequency Reaction: 45Hz~ 18KHz.
Running Temperature level: -10~ 55 ℃.
Dimensions: 296x140x130mm.


Network Sound Bridge GEN-3101A01


Power Supply: POE.
Interaction Method: TCP/IP, UDP, SIP.
Signal-to-Noise Proportion: > 85dB.
Frequency Feedback: 50Hz~ 20KHz.
Running Temperature: -10~ 55 ℃.
Measurements: 126x66x27mm.


Network Digital Amplifier XC-9508P


Power Supply: AC100V~ 240V, 50/60Hz.
Power: 130W, 260W, 360W, 500W.
Interaction Protocol: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 80dB.
Frequency Reaction: 60Hz~ 18KHz.
Running Temperature level: -10~ 50 ℃.
Dimensions: 440x300x44mm.


Zone Mixing Digital Amplifier NBS-2301


Power Supply : AC 220V, 50Hz.
Power : 130W , 260W , 360W , 550W , 700W.
Communication Protocol : HTTP, TCP/IP, UDP, ARP, ICMP, IGMP.
Signal-to-Noise Ratio :.
Mic Input 01: ≥ 65dB,.
Mic Input 02/03: ≥ 80dB,.
Aux Input 01/02: ≥ 82dB.
Frequency Feedback :.
Mic Input 01: 80Hz~ 14kHz.
Mic Input 02/03: 60Hz~ 16kHz.
Aux Input 01/02: 60Hz~ 16kHz.
Operating Temperature :.
10 ℃~ +50 ℃ (14 ℉~ 122 ℉)
Dimensions : 483x430x88mm.


IP User Interface Device NAC-5003


Power Supply: AC100V~ 240V, 50/60Hz.
Communication Procedure: TCP/IP, UDP.
User interfaces: 1 Ethernet port, 32 alarm system inputs, 8 alarm outcomes.
Operating Temperature: -10~ 50 ℃.
Dimensions: 483x259x44mm.


Remedy For College





Adaptable Zoning Program:


The fully network terminals can realize adaptable zoning options, enabling relaying notices to different zones or private terminals ( gadgets).


Institution Bell System:


It gives college bell system at the beginning/ending of the class - IP Speaker. Multiple circumstances can be created, including various arranged broadcast tasks according to summer/winter schedule


Emergency Alarm Combination


It sustains assimilation with emergency alarm systems, permitting smoke alarm signals to be incorporated right into the PA system.


Classroom Sound Amplification


Terminals sustain daily applications in class scenes. They can be linked to projectors or interactive white boards for audio boosting.


Spon CommunicationsIp Paging Microphone

Smart Street Lamp/Security Pole



Assistance SIP Method:


Integrated SIP procedure for seamless integration with network communication systems.


VMS Operatings Systems Integration:


Integrated ONVIF method for combination with VMS systems.


Third-Party Assimilation:


Developed in HTTP API for integration with 3rd celebration systems.


Voice Alarm System Causing:


Constructed in alarm input user interface for triggering voice alarm systems with cameras.


Service For Hotel



Zone Control by Flooring:


The system offers complete network settings, splitting areas depending on various floorings and control over each zone individually.


Fire Alarm System Integration:


The system can be incorporated with smoke alarm system, making it possible for integration of fire alarm signals into the broadcasting system.


Scheduled Broadcasting:


It supports programmable arranged broadcasting, permitting adaptable setups according to numerous demands.


Emergency situation Broadcasting:


It sustains emergency broadcasting for the entire location, making it possible for one-click emergency situation communication.


Remedy For Manufacturing facility



Zone Broadcasting:


It enables relaying to any kind of zone, guaranteeing no disturbance in between different areas.


Alarm system Triggering:


Terminals have numerous sort of interfaces, making it possible for to set off alarms when attached with cams.


All Network Devices:


Deployment of completely network devices dramatically reduces the difficulty of running such as checking gadgets on dangerous websites, and therefore safeguarding people and browse around this site property.


The implementation of all network gadgets substantially minimizes the problem of procedure and upkeep monitoring


Integrated SIP Phones:


The system can be integrated with SIP phone and broadcast notices utilizing SIP phones any time and anywhere. Two-way sound talkback between SIP phones and IP POE Audio speakers makes it simple for checking gadgets sitting in workplace or various other work environments.


The XC-9000 system is a fully digital network PA system based on the TCP/IP method. By leveraging the TCP/IP procedure, the system ensures the effective and proper transmission of all information packets. The system sustains numerous types of audio resources for sending alerts like live speech and BGM playback. In addition, the system supplies varied functions of sustaining different broadcasting features such as set up broadcasting, zoned broadcasting, and emergency situation broadcasting.


The system can be incorporated with the fire alarm system for control.

Report this page